AIR-GAP EFFECTS ON NEUTRON TRANSPORT AND SECONDARY RADIATION IN POLYETHYLENE–CONCRETE FAST-NEUTRON SHIELDING
DOI:
https://doi.org/10.24036/mtvncg98Keywords:
Air gap, Monte Carlo, PHITS, neutron shielding, plyethylene, concreteAbstract
The presence of an air gap between layers of radiation shielding can affect neutron transport characteristics and radiation protection effectiveness. This study aims to analyze the effect of variations in air gap thickness on neutron transport in two shielding configurations: polyethylene–concrete (PE–Concrete) and concrete–polyethylene (Concrete–PE). Simulations were performed using the Monte Carlo method with PHITS software and a 1 MeV monoenergetic neutron source. Both materials had a thickness of 5 cm, while the air gap was varied to 0, 1, 2, 5, 10, and 20 cm. The parameters analyzed included neutron flux and energy distribution, neutron production, and relative neutron and photon leakage. The simulation results showed that increasing the air gap to 20 cm caused neutron leakage to increase by 23% in PE–Concrete and 21% in Concrete–PE, while photon leakage decreased by 4% and 8%, respectively. The increase in neutron leakage shows a trend consistent with the rise in neutron flux based on the T-Cross results and the neutron production recorded in the simulation. The neutron energy distribution is dominated by fast neutrons, with their fraction tending to increase as the air gap increases. These results indicate that the air gap thickness and material sequence affect radiation transport characteristics and that adding an air gap does not improve neutron retention effectiveness in either of these configurations.
References
[1] Y. Lei, P. Xu, C. Lu, Y. Wang, and W. Yu, “Study on geometric scattering effects correction for precise estimation of fast neutron shielding in polyethylene materials,” Appl. Sci., vol. 16, p. 1345, Jan. 2026.
[2] K. Ueki and Y. Namito, “Optimum arrangement to minimize total dose rate of iron-polyethylene shielding system,” J. Nucl. Sci. Technol., vol. 26, pp. 411–421, Apr. 1989.
[3] ALMisned, Ghada, D. S. Baykal, W. Elshami, G. Susoy, G. Kilic, and H.O. Tekin, "A comparative analysis of shielding effectiveness in glass and concrete containers," Open Physics, vol. 22, pp. 20240019, 2024.
[4] X. Wang and R. E. Faw, “Transmission of neutrons and secondary Gamma Rays through concrete slabs,” Radiat. Prot. Dosimetry, vol. 60, pp. 213–222, Jul. 1995.
[5] H.H. Park, E. Song, J. Kim, and C. Kim, “Impact of Air Gaps Between Microstrip Line and Magnetic Sheet on Near-Field Magnetic Shielding,” Electronics, vol. 13, p. 4313, 2024.
[6] G. Yao, M. Qiao, D. Ma, B. Zhang, “A novel level-shifting technique with air-gap self-shielding structure for 700 V high-voltage gate driver ICs,” Microelectronics Journal, vol. 169, p. 107036, 2026.
[7] T. D. Bohm, L. El-Guebaly, and ARIES Team, “Novel solution for the problem of the neutron streaming through inboard assembly gaps of ARIES Tokamak power plants,” Fusion Sci. Technol., vol. 60, pp. 278–282, Jul. 2011.
[8] S. J. Park, J. G. Jang, and H. K. Lee, “Computational investigation of the neutron shielding and activation characteristics of borated concrete with polyethylene aggregate,” J. Nucl. Mater., vol. 452, pp. 205–211, Sep. 2014.
[9] G.S.M. Ahmed, “Neutron shielding: Advanced mechanisms, challenges, and material strategies,” Radiation Physics and Chemistry, vol. 241, p. 113544, 2026.
[10] H. Zhai, S. Zhong, J. Li, Y. Chen, Y. Cui, Z. Chen, G. Sun, H. Wang, “The neutron shielding modeling and experimental characteristic in TiB2/Al composites,” Materials Today Communications, vol. 27, p. 102194, 2021.
[11] S. Agostinelli et al., “Geant4—a simulation toolkit,” Nucl. Instrum. Methods Phys. Res. A, vol. 506, pp. 250–303, Jul. 2003.
[12] T. Sato et al, “Features of particle and heavy ion transport code system (PHITS) version 3.02,” J. Nucl. Sci. Technol., vol. 55, pp. 683–690, Jan. 2018.
[13] T. Sato et al., “Recent improvements of the particle and heavy ion transport code system – PHITS version 3.33,” J. Nucl. Sci. Technol., vol. 61, pp. 127–135, May. 2024.
[14] T. Goorley et al., “Initial MCNP6 release overview,” Nucl. Technol., vol. 180, pp. 298–315, Dec. 2012.
[15] T. Cui, F. Wang, L. Bing, R. Wang, Z. Ma, Q. Jia, “Monte Carlo simulation and optimization of neutron ray shielding performance of related materials, Nuclear Engineering and Technology, vol. 56, pp. 3545-3552, 2024.
[16] S. Yani, T. S. N. Kholis, D. T. Tai, N. Tamam, A. Sulieman, T. Sumaryada, Akhiruddin, S. T. Wahyudi, I. Arif, “Assessment of proton shielding properties of rare earth metal-concrete using PHITS Monte Carlo code,” Radiation Physics and Chemistry, vol. 236, p. 112908, 2025
[17] M. S. Beni, T. C. Hau, D. Krstic, D. Nikezic, and K. N. Yu, “Monte Carlo studies on neutron interactions in radiobiological experiments,” PLoS ONE, vol.12, Jul. 2017.
[18] H. Hashikura, H. Fukumoto, Y. Oka, M. Akiyama, and S. An, “Neutron streaming through a slit and duct in concrete shields and comparison with a Monte Carlo analysis,” Nucl. Sci. Eng., vol. 84, pp. 337–344, Aug. 1983.
[19] D. Hadju, E. Dian, E. Klinkby, C. P. Cooper-Jensen, J. Osan, and P. Zagyvai, “Neutron activation properties of PE-B4C-concrete assessed by measurements and simulations,” J. Neutron Res., vol. 21, pp. 87–94, 2019.
[20] J. C. Liu and T.T. Ng, “Monte Carlo calculations using MCNP4B for an optimal shielding design for a 14 MeV neutron source,” Radiat. Prot. Dosimetry, vol. 83, pp. 257–262, Jul. 1999.
[21] H. R. Vega-Carrillo, L. E. Villagrana-Munoz, E. Rivera-Perez, H. A. de Leon-Martinez, T. G. Soto-Bernal, and V. M. Hernandez-Davila, “Concrete enclosure for shielding a neutron source,” Appl. Radiat. Isot., vol. 79, pp. 37–41, Sep. 2013.
[22] D. Munteanu, J. L. Autran, S. Moindjie, M. Cecchetto, and M. Dentan, “Neutron shielding by concrete slabs and its impact on the soft-error rate of electronics in nuclear fusion,” Appl. Sci., vol. 16, p. 7139, Jul. 2026.
Published
Issue
Section
License
Copyright (c) 2026 Sitti Yani, Tony Sumyarada, Abd. Djamil Husin, Tesa Valentina Sembiring (Author)

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.